VR722 LUCY Repair Tips
Search: VR722 LUCY
Results 1
Results 1
Make | Model Ch. | Symptom | Problem Solution | Solution | By: |
---|---|---|---|---|---|
Philips | VR722 LUCY | LSM-45 power supply faulty after power failure | Replaced elco 2112 100µF, 385V and capacitor 2116 100nF, 400V. See also my tip about the philips VR-723 Cooling down during power outtage. Cheers |