VR722 LUCY Repair Tips




Search: VR722 LUCY
Results 1
MakeModel Ch.SymptomProblem SolutionSolutionBy:
Philips VR722 LUCY
LSM-45 power supply faulty after power failureReplaced elco 2112 100µF, 385V and capacitor 2116 100nF, 400V. See also my tip about the philips VR-723 Cooling down during power outtage. Cheers